Katrangan Singkat:

Contactor AC Series C7S kanthi tampilan novel lan struktur kompak cocog kanggo nggunakake wiwitan & ngontrol AC motor asring. Ngalih lan mateni sirkuit kanthi jarak sing dawa. Iki digunakake ing kombinasi karo relay termal kanggo nyusun wiwitan motor magnet.standard: IEC 60947-1. IEC 60947-4-1.


Detail Produk

Tag Produk

Ketik C7S-09 C7S-12 C7S-18 C7S-25 C7S-32 C7S-38 C7S-40 C7S-50 C7S-65 C7S-80 C7S-95
Karakteristik Circuit Utama
Cagak 3P
Rated insulasi insulasi voltagelayu) V 690
Voltagel operasi sing dirating) V 380 / 400,660 / 690
Saiki termal thermal (lth), AC-1 20 20 32 40 50 50 60 80 80 125 125
Dirating
Operasi
Saiki (le)
AC-3,380 / 400V A 9 12 18 25 32 38 40 50 65 80 95
AC-3,660 / 690V A 6.6 8.9 12 18 22 22 34 39 42 49 49
AC-4,380 / 400V A 3,5 5 7.7 8.5 12 14 18.5 24 28 37 44
AC-4,660 / 690V A 1.5 2 3.8 4.4 7,5 8.9 9 12 14 17.3 21.3
Dirating
operasional
Powerlpe)
AC-3,380 / 400V kW 4 5.5 7,5 11 15 18.5 18.5 22 30 37 45
AC-3,660 / 690V kW 5.5 7,5 10 15 18.5 18.5 30 33 37 45 45
AC-4,380 / 400V kW 1.5 2.2 3.3 4 5.4 5.5 7,5 11 15 18.5 22
AC-4,660 / 690V kW 1.1 1.5 3 3.7 5.5 6 7,5 10 11 15 18.5
Urip mekanik 1200 1000 900 650
Urip listrik Ac-3 10000
kaping
110 90 65
AC-4 22 22 17 11 C7S-09 ~ 38
Frekuensi
Operasi
Ac-3 kaping /
jam
1200 600
AC-4 300 300
Kapabilitas Nyambungake Terminal Sirkuit Utama
Kawat Fleksibel 1 kawat mm² 1 ... 4 1.5 ... 6 2,5 ... 25 4 ... 50
Ora terminal 2 kawat mm² 1 ... 4 1.5 ... 6 2.5 ... 16 4 ... 25
Kawat Fleksibel 1 kawat mm² 1 ... 4 1 ... 6 2,5 ... 25 4 ... 50
Karo terminal 2 kawat mm² 1 ... 2,5 1 ... 4 2.5 ... 10 4 ... 16
Kabel Hard 1 kawat mm² 1 ... 4 1.5. ... 6 1.5. ... 10 2,5 ... 25 4 ... 50
Ora terminal 2 kawat mm² 1 ... 4 1.5 ... 2.5 ... 10 4 ... 25
Torsi Fastening N · m 1.2 1.8 5 9
Coil
Kontrol dirating
Voltagal)
50hz V 24,36,48,110,2,27,27,27,27,27,27,27,240,380 / 400,415,440
50 / 60hz V 24,36,48,110,2,27,27,27,27,27,27,27,240,380 / 400,415,440
Kontrol sing nggumunake
Circuit Voltagallus)
Operasi V Angole Instalasi Instalasi ± 22.5 °: 85% ~ 110% AS; sudut karep instalasi ± 5 °: 70% ~ 120%
Rilis V Angole Instalasi Instalasi ± 22.5 °: 20% ~ 75% AS; Angle Instalasi Instalasi ± 5 °: 20% ~ 65%
Kekuwatan
Konsumsi
saka coil
Actuation VA 60 70 200 200
Terus VA 6-9.5 6-9.5 15-20 15-20
Konsumsi W 1-3 1-3 6-10 6-10
Kontak bantu Jinis amax Amax Bmax Cmax a d e
C7S-09.12.18 74.5 45.5 85.5 35 50/60
Spesifikasi Kontak Bantu A 11
C7S-25.32.38 83 56.5 97 40 50/70 - - -
Saiki termal Thermal (ITH) A 10
C7S-40.50,65 127.5 74.5 117 105 40 100/110 59
Ngolah Operasi
voltase (ue)
AC V 380
C7S-80.95 127.5 85.5 125.5 105 40 100/110 67
DC V 220
Kontrol dirating
capacit
AC-15 VA 360
DC-13 W 33