Kompresor Udara Spesial TechnolotyParameter Lan Mode (WQC)
Jinis | daya | Tegangan | Rated saiki | Thermal relay bagean diatur orane katrangan |
WQC-12 | 0,75KW | 380V | 2.1A | 1.7-2.5A |
WQC-12 | 1.1KW | 380V | 2.5A | 2-3A |
WQC-12 | 1.5KW | 380V | 3.6A | 2.8-4.4A |
WQC-12 | 2.2KW | 380V | 5A | 4-6A |
WQC-12 | 3KW | 380V | 6.6A | 5.2-8A |
WQC-32 | 4KW | 380V | 9A | 7-11A |
WQC-32 | 5,5KW | 380V | 11A | 9-13A |
WQC-32 | 7,5KW | 380V | 15A | 12-18A |
WQC-32 | 11KW | 380V | 22A | 20-32A |
WQC-50 | 15KW | 380V | 30A | 28-45A |
WQC-50 | 18,5KW | 380V | 37A | 40-63A |
WQC-65 | 18,5KW | 380V | 37A | 40-63A |
WQC-85 | 22KW | 380V | 44A | 40-63A |
WQC-95 | 30KW | 380V | 60A | 53-85A |
Jinis | Kontaktor | Relay termal standar | Kontrol daya motor (KW) | Rated saiki (A) | ||||
Jinis | Setel saiki | 220V | 380V | 500V | 220V | 380V | ||
QCX5-9 | CJX5-9 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 11 | 9 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 11A | 3 | 5.5 | 7.5 | 13 | 12 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 29A | 7.5 | 15 | 18.5 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 35A | 9 | 18.5 | 22 | 40 | 40 |
Ukuran lan Pemasangan ukuran
■ Starter bisa suwe lan ora bisa digunakake relay termal. Frekuensi bisa 600 kaping / jam ing wektu cendhak lan bola-bali digunakake;
■ Attraction coil andal bisa digunakake nalika 85% ~ 105% voltase dirating, Iku dirilis voltase kira-kira 40 ~ 55% voltase dirating;
■ Kontak wiwitan ing frekuensi operasi 600 / jam, telegram bunder terus kanggo mimpin kanggo patut 40%. Nempatno liwat saiki nominal sijine liwat, nalika pamisahan faktor punika 0,35, Iku urip electrical ora luwih murah tinimbang 640.000 kaping;
■ Urip mekanik wiwitan yaiku 3 yuta kaping;
■ Kontak tambahan wiwitan, iku saiki nominal 5A;
■ Relay termal nduweni organisasi kompensasi suhu, Bisa ngimbangi suhu sing disebabake dening owah-owahan voltase suhu lingkungan;
■ Thermal relay overload punika karo stipulations. Kanggo ndeleng ing ngisor iki.